Thermocouple Test RIG Specification

  • Accuracy
  • 1C
  • Number of Specimens
  • 1-4
  • Mounting Type
  • Floor standing
  • Port Size
  • 1/4 inch BSP
  • Resolution
  • 0.1C
  • Max Height
  • 1.2 meters
  • Interface Type
  • RS232 / USB (optional)
  • Test Range
  • Room temperature to 1200C
  • Temperature
  • Ambient to 1200C
  • Humidity
  • 20-90% RH
  • Equipment Type
  • Test Rig
  • Response Time
  • <1 second
  • Power Supply
  • 230V AC, 50Hz
  • Gas Pressure
  • 0-10 bar
  • Display Type
  • Digital LED display
  • Features
  • Data logging, Overheat protection, Programmable set point
  • Operating Voltage
  • 230V AC
  • Automation Grade
  • Semi-automatic
  • Frequency
  • 50Hz
  • Specimen Size
  • 1.5 mm to 10 mm diameter
  • Measuring Range
  • 0C to 1200C
  • Application
  • Testing accuracy and response of thermocouples
  • Usage
  • Laboratory and industrial thermocouple testing
  • Capacity
  • Standard 4 thermocouple sockets
  • Machine Weight
  • Approx. 60 kg
  • Test Speed
  • Configurable (typically 2-10 mm/min)
  • Test Width
  • Up to 250 mm
  • Test Stroke
  • Up to 150 mm
  • Control Mode
  • Digital PID temperature controller
  • Power Consumption
  • Approx. 1.2 kW
  • Protection Grade
  • IP20
  • Insulation Type
  • Ceramic fiber blanket
  • Ambient Operating Conditions
  • 5°C to 50°C, non-condensing
  • Furnace Material
  • High grade Kanthal wire heating
  • Data Output
  • Digital logging to PC
  • Heat Up Time
  • within 30 minutes to max temperature
  • Cooling System
  • Natural convection or assisted air cooling (optional)
  • Calibration Reference
  • Standard certified thermometer input
  • Thermocouple Types Supported
  • J, K, T, R, S, B, N
  • Safety Features
  • Emergency stop, Over-temperature cut-off
  • Chamber Volume
  • Approx. 7 Liters
 
 

About Thermocouple Test RIG



Select the Thermocouple Test RIG for an unrivaled testing experience, designed for eminent precision and radiant efficiency. This hot deal combines high-grade Kanthal wire heating with ceramic fiber insulation, ensuring safety through emergency stop and over-temperature cut-off features. Operating from 5C to 50C, this device achieves max temperatures of 1200C within 30 minutes, supporting J, K, T, R, S, B, N thermocouple types. Enjoy digital data logging, configurable test speeds, and programmable controls. Save on quality with robust design, IP20 protection, and efficient energy consumptionideal for laboratories and industrial suppliers across India.

Reliable Performance in Thermocouple Testing

The Thermocouple Test RIG is used for accurate measurement and response validation of thermocouples. Crafted with high-grade Kanthal wire and robust ceramic fiber insulation, this equipment ensures unmatched durability and thermal stability. Suitable for various laboratory and industrial surfaces, its floor-standing mount and semi-automatic operation make it versatile for all application areas. Experience radiant operational control, optimal for routine and specialized thermocouple assessments ranging from ambient to 1200C with exceptional accuracy.


Global Market Reach and Sample Policy

We estimate the Thermocouple Test RIG has a growing market value, supplying high-quality units to export markets such as the Middle East, Southeast Asia, and Europe. Samples are available for qualified buyers under our transparent sample policy, enabling detailed evaluation of the rig before bulk purchasing. This approach ensures that potential clients can assess the eminent features and savings benefits first-hand, reinforcing confidence in our export and supplier commitments.


FAQs of Thermocouple Test RIG:


Q: How does the Thermocouple Test RIG enhance testing accuracy?

A: The rig uses a standard certified thermometer input for calibration reference, digital PID temperature control, and precise heating elements, resulting in measurement accuracy within 1C and a resolution of 0.1C.

Q: What types of thermocouples can be tested with this rig?

A: It supports a broad range of thermocouple types including J, K, T, R, S, B, and N, allowing for flexible application across various industrial and laboratory environments.

Q: When is the ideal time to use this equipment?

A: The Thermocouple Test RIG operates best in ambient conditions from 5C to 50C and humidity levels between 20-90% RH, making it suitable for most standard laboratory and industrial testing schedules.

Q: Where is this rig commonly supplied or exported?

A: It is supplied mainly to laboratories and industries in India and exported to markets in the Middle East, Southeast Asia, and Europe, among others.

Q: What is the process for digitally logging test data?

A: The device features digital output for PC logging via RS232 or optional USB interface, allowing for efficient and accurate record-keeping during and after test runs.

Q: What safety features are included in the Thermocouple Test RIG?

A: Safety is assured through an emergency stop, over-temperature cut-off, and IP20 protection grade, providing secure operation during rigorous testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing Equipment Category

PROCTOR NEEDLE APPARATUS

PROCTOR NEEDLE APPARATUS

Price 15200.0 INR / Piece

Minimum Order Quantity : 1 Number, Number

Mounting Type : Bench top

Port Size : Standard

Number of Specimens : Single specimen per test

Accuracy : 1% of full scale

Automatic Bituminous Compactor

Automatic Bituminous Compactor

Price 80500 INR / Number

Minimum Order Quantity : 1 Number

Mounting Type : Floor mounted

Port Size : Standard 1/2 inch

Number of Specimens : 1 at a time

Accuracy : 1 mm

Split AC Test RIG

Split AC Test RIG

Mounting Type : Floor Mounted

Port Size : 1/2 inch and 1/4 inch Quick Connect

Number of Specimens : 1 unit per test cycle

Accuracy : 0.5% full scale

D Freezer Test RIG

D Freezer Test RIG

Mounting Type : Floor Standing

Port Size : 1/2 inch

Number of Specimens : Up to 5

Accuracy : 1% of reading